2653 Warfield Street Fort Worth, TX 76106 USA |
Flame Safe FIRE RETARDANT Coatings / Flame RetardantsHotline: 800-333-9197 8am-5pm (CST) Ph: 817-740-9197 After Hours: 817-658-9197 email: fireprod@aol.com |
Dallas, Fort Worth, Houston, Austin,South Dallas, North Dallas, Dallas County, Houston, Corpus Christi, San Antonio, Dallas - Fort Worth, Abilene, Amarillo, Odessa, Midland, El Paso |
HOME | CONTACT US | PRODUCTS | SDS Fire Poly FP50CC | TESTING |
Fire Retardant Coatings - Flame Retardant Coatings - Fire Retardant Sprays |
FIRE POLY FP50CC
INTERIOR FIRE RETARDANT COATING or SPRAY FOR ARTIFICIAL PLANTS, FOLIAGE and ARTIFICIAL CHRISTMAS TREES |
FIRE RETARDANT COATING
SURFACE BURNING CHARACTERISTICS OF APPLIED COATING
Flame spread | 0.0 - 5 |
Smoke developed | 190 |
Number of preliminary coats | None |
Rate per coat (ft2/gal) | 200 |
Number of fire retardant coats | 1 |
Number of overcoats | None |
Rate per coat (ft2/gal) | -- |
Flash point of liquid coating: | |
Fire retarding coating - closed cup, | no flash |
FIRE POLY FP50CC |
TECHNICAL DATA Fire Poly FP50CC INTERIOR FIRE RETARDANT COATING CLASS A RATING |
---|
PRODUCT DESCRIPTION: Aqueous Based Resin
PRODUCT ANALYSIS | ||||
---|---|---|---|---|
Total Solids |
42 - 46 | PH | 2.6 - 3.2 |
|
Weight per gallon |
10.5 -10.8 lbs | Flash point | Non-Flammable |
|
Specific gravity |
1.3 | Color | Water clear at 78°F. - Slight haze at 50°F. or lower |
|
Volatability |
Non-Volatile | Solvents | Water(Contains no petroleum or derivatives of petroleum) |
|
Anti-Fungus |
Good Resistance | Bacterial | Good Resistance |
|
Linear shrinkage |
None | Moisture Absorption | None |
|
Corrosive |
Mildly | Toxic | None (when dry) |
Volatile Organic Compound - VOC |
RECOMMENDED USE: Interior Class A Rating (Flame spread less than 25)
FLAME SAFE FIRE POLY FP50CC is a fire retardant coating. It can be used on:
Arificial Plants | Artificial Christmas Trees |
Plastic foliage |
ENVIRONMENTAL REGULATION:
This product complies will U. S. Federal Regulations concerning the use of lead in paint and hydrocarbon emissions.
QUICK REFERENCE FOR APPLYING FIRE POLY FP50CC
MATERIAL |
APPLICATION |
COVERAGE |
Interior Artificial plants, AChristmas Trees, |
Treat before, during or after construction. Apply with 80 psi or greater sprayer. Apply fire retardant 8 to 12 inches from surface. |
Apply one coat at 200 sq. ft. per gallon |
INTERIOR All surfaces to be treated must be clean
and dry. Fire Poly FP50CC fire retardant coating is water-based, clear liquid that
becomes insoluble when dry.
Avoid wasteful runs and dripping. It should be noted that unlike some
products, materials treated with Fire Poly FP50CC
fire retardant coating require no special cutting tools or special
fasteners. Contact parts of any equipment
should be stainless steel or plastic to prevent
chemical reaction and breakdown. Storage
may be done in polyethylene containers. |
Fire retardant coating for artificial plants, artificail foliage |
---|
CAUTION:
Product must not freeze. It must not be thinned or diluted.
OVERSPRAY:
The overspray will not harm plants or animals. Spills can be flushed with water. A rag wetted with bleach and water mix will clean up spotting.
CLEAN UP PROCEDURE:
Airless Equipment.
1. Run clear water through the system until coating is flushed out. When minor sudsing on surface stops, the system is flushed.
2. Run bleach and water mix (1 part to 4 parts) through system as solvent for cleaning any residue.
3. Repeat Step 1 if any foaming occurs in Step 2.
4. Lubricate system as specified by equipment manufacturer to combat rusting.
If two or more applications are planned in the same day, the sprayer can be kept clean by running water through the system between applications.
Brushes/Rollers.
1. Clean immediately after use.
2. Wash thoroughly with bleach and water mix (1 part to 4 parts).
SAFETY FIRST
Use approved safety devices (ropes, belts, ridge hooks, ladder, etc.) When working on steep or high areas. Take EXTREME CARE not to step on wet treated area. Surface may be slick until dry.
It is good practice to wear respirator or mask and protect hands with rubber gloves when spraying any coating or chemical. When engineered air control is not feasible, use properly maintained and properly fitted NIOSH approved respirator for solvent vapors. A dusk mask does not provide protection against vapors.
If eye contact occurs, flood with water for fifteen (15) minutes and call a physician. KEEP OUT OF REACH OF CHILDREN. DO NOT TAKE INTERNALLY.
Call for pricing and ordering 1-800-333-9197 |
HOME | CONTACTS | PRODUCTS | SDS Fire Poly FP50CC | TESTING